7-2. Optional Generator Power Receptacles

Notes

YIf unit does not have GFCI re-

ceptacles, use GFCI-

1

protected extension cord.

 

 

 

 

 

. Generator power decreases as

 

weld current increases.

 

 

Combined output of all receptacles

 

limited to 8 kVA/kW rating of the

 

generator.

 

 

 

GFCI Receptacle Option

 

 

1 120 V 20 A AC GFCI Recep-

 

tacles GFCI-2 and GFCI-3

 

GFCI2 and GFCI3 supply 60 Hz

 

single-phase power at weld/power

 

speed.

Maximum

output

from

 

GFCI-2 or GFCI-3 is 2.4 kVA/kW.

 

Circuit breaker protection is the

 

same as standard receptacles.

 

If a ground fault is detected, the

 

GFCI Reset button pops out and

 

the circuit opens to disconnect the

 

faulty

equipment.

Check

for

 

damaged tools, cords, plugs, etc.

 

connected to the receptacle. Press

 

button to reset receptacle and

 

resume operation.

 

 

.At least once a month, run

engine at weld/power speed and press Test button to verify GFCI is working properly.

Ref. 206 422