8-2. Routine Maintenance (Robin EH64-Powered Units)

Note

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an

 

extended period.

 

 

 

Y Stop engine before maintaining.

 

 

. See also Engine Manual and Maintenance Label for im-

 

Recycle

portant start-up, service, and storage information. Ser-

 

vice engine more often if used in severe conditions.

 

engine

 

 

 

fluids.

* To be done by Factory Authorized Service Agent.

 

 

Every 8 h

Check fluid levels. See Section 5-2.

Wipe up spills.

Every 20 h

Every 25 h

Check and clean spark arrestor screen. See Section 8-4.

Service air cleaner wrapper (foam element). See Section 8-3.

Every 50 h

Clean and tighten weld terminals.

Every 100 h

Change oil. See Section 8-6and maintenance label.

Clean cooling system. See Engine Manual.

Service air cleaner element. See Section 8-3.

Clean and tighten battery connections.