9-3. Servicing Air Cleaner (Kohler-Powered Units)

1

2

oil

YStop engine.

YDo not run engine without air cleaner or with dirty element.

1 Wrapper (Foam Element)

Wash wrapper with soap and water solution. Allow wrapper to air dry completely.

Spread 1 tablespoon SAE 30 oil evenly into wrapper. Squeeze out excess oil.

2 Element

Replace element if damaged, dirty, or oily.

aircleaner3 9/00 − 802 772 / Ref. 185 095-A / S-0759

9-4. Servicing Optional Spark Arrestor (Kohler-Powered Units)

Y Stop engine and let cool.

1 Spark Arrestor Screen

Clean and inspect screen. Replace spark arrestor if screen wires are broken or missing.

1

Tools Needed:

1/4 in

802 849-A / Ref. 206 422