4-7. Remote 14 Receptacle RC3 Information (Optional, See Section 4-8)

A J

B K I

C L N H

D M G

EF

Ref. ST-159 730-A

 

Socket*

Socket Information

 

A

24 volts ac. Protected by circuit

 

 

breaker CB4.

 

B

Contact closure to A completes 24

 

 

volts ac contactor control circuit.

 

I

115 volts ac. Protected by circuit

 

 

breaker CB3.

 

J

Contact closure to I completes 115

 

 

volts ac contactor control circuit.

 

G

Circuit common for 24 and 115 volts ac

 

 

circuits.

 

C

0 to +10 volts dc output to remote

 

 

control.

A/V

D

Remote control circuit common.

E

0 to +10 volts dc input command signal

 

 

 

from remote control.

 

K

Chassis common.

*The remaining sockets are not used.

4-8. Terminal Strip 3T Connections (Optional)

Y Stop engine.

If remote control plug does not fit in receptacle RC3, wire cord directly to terminal strip 3T.

Y Do not connect to Remote 14 receptacle RC3 and terminal strip 3T at the same time. Use only one remote control method.

Open right side door.

1 Cover

2 Terminal Strip 3T

Connect leads to 3T using terminal information shown in Section 4-7.

Reinstall cover. Close door.

2

1

Tools Needed:

Ref. ST-139 670-B / ST-185 316 / Ref. ST-191 898

OM-477 Page 17

Page 21
Image 21
Miller Electric Big 40G Remote 14 Receptacle RC3 Information Optional, See Section, Terminal Strip 3T Connections Optional