Miller Electric Big 40G manual Servicing Air Cleaner, Overload Protection, To Clean air filter

Models: Big 40G

1 60
Download 60 pages 18.01 Kb
Page 30
Image 30

7-3. Servicing Air Cleaner

Y Stop engine.

Y Do not run engine without air cleaner or with dirty element.

Clean or replace element if dirty or damaged. Replace element yearly or after six cleanings.

1 Dust Cap

5

4

3

2

1

2 Baffle

3 Element

4 Plastic Fins

5 Housing

To Clean air filter:

Wipe off cap and housing. Remove cap and dump out dust. Wipe dust from inside cap and housing with damp cloth. Remove element and reinstall cap.

Y Do not clean housing with air hose.

Clean element with compressed air only. Keep nozzle at least 1 in (25 mm) from inside of element. Max. air pressure: 100 psi (690 kPa). Do not remove plastic fins. Replace ele- ment if it has holes or damaged gaskets.

Reinstall element and cap (cap arrows pointing up).

BlowInspect

aircleaner1 6/96 – ST-153 929-B / ST-153 585 / Ref. ST-191 898 / Ref. S-0698-B

7-4. Overload Protection

Y Stop engine.

. If any fuse or circuit breaker continues to open, contact Fac- tory Authorized Service Agent.

1 Magnetic Shutdown

Switch MS1

2 Fuse F (See Parts List)

Fuse F protects magnetic shutdown switch MS1. If fuse F opens, the engine stops.

Check fuse and replace if open.

3 Circuit Breaker CB3 (Optional)

4 Circuit Breaker CB4 (Optional)

CB3 protects the 115 volt ac output and CB4 protects the 24 volt ac out- put to optional Remote 14 recep- tacle RC3 and terminal strip 3T. If a circuit breaker opens, 24 or 115 volts ac output stops.

1

3

4

Press button to reset breaker.

2

Tools Needed:

Ref. ST-159 730-A / Ref. ST-191 898

OM-477 Page 26