Miller Electric Bobcat 225 manual Operating Auxiliary Equipment, Standard Receptacles

Models: Bobcat 225

1 78
Download 78 pages 2.49 Kb
Page 34
Image 34

. A complete Parts List is available at www.MillerWelds.com

SECTION 7 − OPERATING AUXILIARY EQUIPMENT

7-1. Standard Receptacles

 

 

 

 

 

!

If unit does not have GFCI re-

 

 

 

 

 

 

ceptacles, use GFCI-protected

 

 

 

 

 

 

extension cord.

 

 

 

 

 

 

. Generator power decreases as

 

 

 

 

 

 

weld current increases.

 

 

 

 

 

 

 

Set Fine Control R1 at 10 for full

 

 

 

 

 

 

generator power.

 

 

 

 

 

 

1

240 V 50 A AC Receptacle RC1

 

 

 

 

 

RC1 supplies 60 Hz single-phase

 

 

 

 

 

power at weld/power speed. Maxi-

 

 

 

 

 

mum output is 10 kVA/kW.

 

 

 

 

 

 

2

120 V 20 A AC Duplex Recep-

 

 

 

 

 

 

tacle RC2

 

 

 

 

 

 

 

3

120 V 20 A AC Duplex Recep-

 

 

 

 

 

 

tacle RC3

 

 

 

 

 

 

 

RC2 and RC3 supply 60 Hz single-

 

 

 

 

 

phase power at weld/power speed.

 

 

 

 

 

Maximum output from RC2 or RC3 is

 

 

 

 

 

2.4 kVA/kW.

 

 

 

 

 

 

 

4

Supplementary Protector CB1

 

 

 

 

 

CB1 protects receptacles RC1, RC2,

 

 

 

 

 

and RC3 from overload. If CB1

 

 

 

 

 

opens, the receptacles do not work.

1

5

2

6

3

Place switch in On position to reset.

5

Supplementary Protector CB2

 

 

 

 

 

 

 

 

 

 

6

Supplementary Protector CB3

 

 

 

 

 

CB2 protects RC2 and CB3 protects

 

 

 

 

 

RC3 from overload. If a supplementa-

 

 

 

 

 

ry protector opens, the receptacle

 

 

 

 

 

does not work.

 

 

 

 

 

 

 

. Press button to reset. If supple-

 

 

 

 

 

 

mentary protector continues to

 

 

 

 

 

 

open,

contact

Factory

 

 

 

 

 

 

Authorized Service Agent.

 

 

 

 

 

Combined output of all receptacles

 

 

 

 

 

limited to 10 kVA/kW rating of the gen-

 

 

 

 

 

erator.

 

 

 

 

 

 

 

EXAMPLE: If 20 A is drawn from

 

 

 

 

 

each 120 V duplex receptacle, only

 

 

 

 

 

21 A is available at the 240V

 

 

 

 

 

receptacle:

 

 

 

 

 

 

 

2 x (120 V x 20 A) + (240 V x 21 A) =

 

 

 

 

 

10 kVA/kW

 

 

4

803 847-C / Ref. 228 199-A

OM-4434 Page 30

Page 34
Image 34
Miller Electric Bobcat 225 manual Operating Auxiliary Equipment, Standard Receptacles