Miller Electric Bobcat 225 manual Generator Power Guidelines, Selecting Equipment

Models: Bobcat 225

1 78
Download 78 pages 2.49 Kb
Page 54
Image 54

SECTION 13 − GENERATOR POWER GUIDELINES

.The views in this section are intended to be representative of all engine-driven welding generators. Your unit may differ from those shown.

13-1. Selecting Equipment

1

2

3

OR

1Generator Power Receptacles − Neutral Bonded To Frame

23-Prong Plug From Case Grounded Equipment

32-Prong Plug From Double Insulated Equipment

.Be sure equipment has double

insulated symbol and/or word- ing on it.

Do not use 2-prong plug un- less equipment is double in- sulated.

gen_pwr 2007−04 − Ref. ST-159 730 / ST-800 577

13-2. Grounding Generator To Truck Or Trailer Frame

1

GND/PE2

3

Always ground generator frame to vehicle frame to pre- vent electric shock and static electricity hazards.

Also see AWS Safety & Health Fact Sheet No. 29, Grounding of Portable And Vehicle Mounted Welding Generators.

1Equipment Grounding Terminal (On Front Panel)

2Grounding Cable (Not Supplied)

3Metal Vehicle Frame

Connect cable from equipment ground terminal to metal vehicle frame. Use #10 AWG or larger insulated copper wire.

.Electrically bond generator frame to vehicle frame by met- al-to-metal contact.

Bed liners, shipping skids, and some running gear insu- late the welding generator from the vehicle frame. Al- ways connect a ground wire from the generator equip- ment grounding terminal to bare metal on the vehicle frame as shown.

If unit does not have GFCI re- ceptacles, use GFCI-pro- tected extension cord.

S-0854

OM-4434 Page 50

Page 54
Image 54
Miller Electric Bobcat 225 Generator Power Guidelines, Selecting Equipment, Grounding Generator To Truck Or Trailer Frame