| . A complete Parts List is available at www.MillerWelds.com |
|
|
Trouble | Remedy |
|
|
No generator power or weld output. | Be sure all equipment is disconnected from receptacles when starting unit. |
|
|
| Check fuses F1 and F2, and replace if open (see Section |
|
|
| Check plug PLG6 connection. |
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, capacitor C1, and integrated rectifi- |
| ers SR2 and SR3. |
|
|
Low power output at ac receptacles. | Check fuse F2, and replace if open (see Section |
|
|
| Increase Fine control R1 setting to max. |
|
|
High power output at ac receptacles. | Check engine speed, and adjust if necessary (see Section |
|
|
Erratic power output at ac receptacles. | Check fuel level. |
|
|
| Check engine speed, and adjust if necessary (see Section |
|
|
| Check receptacle wiring and connections. |
|
|
| Have Factory Authorized Service Agent check brushes and slip rings. |
|
|
10-3. Engine Troubleshooting
Trouble | Remedy | |
|
| |
Engine will not crank. | Check fuse F6, and replace if open (see Section | |
|
| |
| Check battery voltage. | |
|
| |
| Check battery connections and tighten if necessary. | |
|
| |
| Check plug PLG4 and plug PLG8 connections. | |
|
| |
| Have Factory Authorized Service Agent check Engine Control switch S2. | |
|
| |
Engine will not start. | Check fuel level. | |
|
| |
| Check battery voltage. | |
|
| |
| Check battery connections and tighten if necessary. | |
|
| |
| Check oil level (see Section | |
|
| |
| Check low oil pressure shutdown switch. | |
|
| |
| Have Factory Authorized Service Agent check fuel shutoff solenoid FS1 and diode D8. (FS1 optional on | |
| ||
|
| |
Engine starts but stops when Engine | Check oil level. | |
Control switch returns to Run position. |
| |
Check and refill crankcase with proper viscosity oil for operating temperature, if necessary. | ||
| ||
|
| |
| Check low oil pressure shutdown switch. | |
|
| |
Engine stopped during normal | Check fuel level. | |
operation. |
| |
|
| |
| Check oil level (see Section | |
|
| |
| Check low oil pressure shutdown switch. | |
|
| |
| Periodically recharge battery (approximately every 3 months). | |
|
| |
| Replace battery. | |
|
| |
| Check voltage regulator and connections according to engine manual. | |
|
| |
| Have Factory Authorized Service Agent check fuel shutoff solenoid FS1 (FS1 optional on | |