Trouble

Remedy

 

 

No generator power or weld output.

Be sure all equipment is disconnected from receptacles when starting unit.

 

 

 

Check fuses F1 and F2, and replace if open (see Section 8-7or 9-6).

 

 

 

Check plug PLG6 connection.

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, capacitor C1, and integrated rectifi-

 

ers SR2 and SR3.

 

 

Low power output at ac receptacles.

Check fuse F2, and replace if open (see Section 8-7or 9-6).

 

 

 

Increase Fine control R1 setting to max.

 

 

High power output at ac receptacles.

Check engine speed, and adjust if necessary (see Section 8-6or 9-5).

 

 

Erratic power output at ac receptacles.

Check fuel level.

 

 

 

Check engine speed, and adjust if necessary (see Section 8-6or 9-5).

 

 

 

Check receptacle wiring and connections.

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings.

 

 

10-3. Engine Troubleshooting

Trouble

Remedy

 

 

Engine will not crank.

Check fuse F6, and replace if open (see Section 8-7or 9-6).

 

 

 

Check battery voltage.

 

 

 

Check battery connections and tighten if necessary.

 

 

 

Check plug PLG4 and plug PLG8 connections.

 

 

 

Have Factory Authorized Service Agent check Engine Control switch S2.

 

 

Engine will not start.

Check fuel level.

 

 

 

Check battery voltage.

 

 

 

Check battery connections and tighten if necessary.

 

 

 

Check oil level (see Section 5-2or 5-3).

 

 

 

Check low oil pressure shutdown switch.

 

 

 

Have Factory Authorized Service Agent check fuel shutoff solenoid FS1 and diode D8. (FS1 optional on

 

Robin-powered units.)

 

 

Engine starts but stops when Engine

Check oil level.

Control switch returns to Run position.

 

Check and refill crankcase with proper viscosity oil for operating temperature, if necessary.

 

 

 

 

Check low oil pressure shutdown switch.

 

 

Engine stopped during normal

Check fuel level.

operation.

 

 

 

 

Check oil level (see Section 5-2or 5-3).

 

 

 

Check low oil pressure shutdown switch.

 

 

 

Periodically recharge battery (approximately every 3 months).

 

 

 

Replace battery.

 

 

 

Check voltage regulator and connections according to engine manual.

 

 

 

Have Factory Authorized Service Agent check fuel shutoff solenoid FS1 (FS1 optional on Robin-powered

 

units).

 

 