Miller Electric Bobcat 250 Engine Prestart Checks Kohler-Powered Units, Open top service door

Models: Bobcat 250

1 76
Download 76 pages 3.71 Kb
Page 23
Image 23

. A complete Parts List is available at www.MillerWelds.com

5-3. Engine Prestart Checks (Kohler-Powered Units)

Full

Full

Gasoline

 

1/2

0

1

H 0000

Check all fluids daily. Engine must be cold and on a level surface. Unit is shipped with 10W30 engine oil.

.Follow run-in procedure in en- gine manual.

NOTICE − This unit has a low oil pressure shutdown switch. Howev- er, some conditions may cause en- gine damage before the engine shuts down. Check oil level often and do not use the oil pressure shutdown system to monitor oil level.

Open top service door.

Fuel

To help prime the fuel system at ini- tial start-up, fill tank with fresh fuel (see maintenance label for specifi- cations). Always leave filler neck empty to allow room for expansion. Check fuel level on a cold engine before use each day.

Oil

.Do not exceed the ”Full” mark on the oil level dipstick. The fuel pump may operate errati- cally if crankcase is overfilled.

After fueling, check oil with unit on level surface. If oil is not up to full mark on dipstick, add oil (see main- tenance label).

.To improve cold weather starting:

Keep battery in good condition. Store battery in warm area.

Use correct grade oil for cold weather.

Close top service door.

803 754-C / 217 015-A

OM-4419 Page 19

Page 23
Image 23
Miller Electric Bobcat 250 manual Engine Prestart Checks Kohler-Powered Units, Open top service door