. A complete Parts List is available at www.MillerWelds.com
5-3. Engine Prestart Checks (Kohler-Powered Units)
Full
Full
Gasoline
| 1/2 |
0 | 1 |
H 0000
Check all fluids daily. Engine must be cold and on a level surface. Unit is shipped with 10W30 engine oil.
.Follow
NOTICE − This unit has a low oil pressure shutdown switch. Howev- er, some conditions may cause en- gine damage before the engine shuts down. Check oil level often and do not use the oil pressure shutdown system to monitor oil level.
Open top service door.
Fuel
To help prime the fuel system at ini- tial
Oil
.Do not exceed the ”Full” mark on the oil level dipstick. The fuel pump may operate errati- cally if crankcase is overfilled.
After fueling, check oil with unit on level surface. If oil is not up to full mark on dipstick, add oil (see main- tenance label).
.To improve cold weather starting:
Keep battery in good condition. Store battery in warm area.
Use correct grade oil for cold weather.
Close top service door.
803