.A complete Parts List is available at www.MillerWelds.com
9-6. Overload Protection (Kohler-Powered Units)
21
. Fuse F6 located in harness behind left side door.
3
.Fuses F1, F2 located on
bracket behind left side panel.
! Stop engine. Disconnect negative (−) battery cable.
1 Fuse F1 (See Section 11-1)
F1 protects the weld excitation winding from overload. If F1 opens, weld output stops or is low.
2 Fuse F2 (See Section
F2 protects the generator power excitation winding from overload. If F2 opens, generator power output stops or is low.
3 Fuse F6 (See Section
F6 protects the engine wiring sys- tem from overload. If F6 opens, engine will not crank.
Replace any open fuses. Reinstall cover before operating.
.If a fuse opens, it usually indi-
cates a more serious problem exists. Contact a Factory Au- thorized Service Agent.
Tools Needed:
3/8 in
803
9-7. Servicing Optional Spark Arrestor (Kohler-Powered Units)
! Stop engine and let cool.
1 Spark Arrestor Screen
Clean and inspect screen. Replace spark arrestor if screen wires are broken or missing.
1
Tools Needed:
1/4 in
803 755 / Ref. 801