6-2. Optional Auxiliary Power Receptacles

1

2

4

3

4

6

5

.Auxiliary power is not affected by weld output.

If a circuit breaker continues to open, contact Factory Autho- rized Service Agent.

GFCI Receptacle Option

1120 V 15 A AC GFCI Receptacle GFCI1

Auxiliary power output and circuit breaker protection is the same as standard receptacles (see Section 6-1).

If a ground fault is detected, GFCI Reset button pops out and receptacle does not work. Check for faulty tools plugged in receptacle. Press button to reset.

.At least once a month, run en-

gine at weld/power speed and press test button to verify GFCI is working properly.

Australian And South African Receptacle Options

2240 V 10 A AC Australian Receptacle RC1

3240 Volt 13 A AC South African Receptacle RC1

RC1 supplies 60 Hz single-phase power at weld/power speed. Maxi- mum output from receptacle is 3 kVA/kW.

4 Circuit Breaker CB1

CB1 protects RC1 from overload. If CB1 opens, RC1 does not work. Press button to reset breaker.

British Receptacle Option

5240 Volt 13 A AC British Receptacles RC1 And RC2

RC1 and RC2 supply 60 Hz single- phase power at weld/power speed. Maximum combined output from both receptacles is 3 kVA/kW.

6 Circuit Breaker CB1

CB1 protects RC1 and RC2 from overload. If CB1 opens, the recep- tacles do not work. Press button to reset breaker.

Ref. ST-180 933-B / Ref. ST-182 266

OM-129 647 Page 25

Page 29
Image 29
Miller Electric 500DX R, OM-129 Optional Auxiliary Power Receptacles, Gfci Receptacle Option, British Receptacle Option