SECTION 7 − MAINTENANCE & TROUBLESHOOTING

7-1. Routine Maintenance

NOTE

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an extended period.

Y Stop engine before maintaining.

Recycle . See also Engine Manual and Maintenance Label.

engine Service engine more often if used in severe

fluids. conditions.

*To be done by Factory Authorized Service Agent.

8 h

Wipe

Up

Spills.

OIL Full

Check Fluid

FUEL

Drain Water

WATER

Levels. See

From Fuel

 

Section 4-5.

 

System.

50 h

Clean Air Filter. See Section 7-3.

Clean And

Tighten

Weld

Terminals.

100 h

Clean And

Tighten

Battery

Connections.

Change Oil. See

Section 7-4.

Change Oil

Filter. See

Section 7-4.

200 h

250 h

Replace

Unreadable

Labels.

Check And

Clean Spark

Arrestor. See

Section 7-9.

500 h

Repair

Or

Replace

Cracked

Cables.

1000 h

Blow Out Or

ORVacuum Inside.

During Heavy

Service,

Clean Monthly.

Service Welding

Generator Brushes

And Slip Rings.

Service More Often

In Dirty Conditions.*

FUEL

Drain Sludge

SLUDGE

From Fuel

 

Tank. See

 

Section 7-4.

Change Fuel

Filters. See

Section 7-4.

1/2 in.

(13 mm)

Check Belt

Tension. See

Section 7-7.

Check

Valve

Clearance.*