Trouble

Remedy

 

 

 

Repair or replace remote control device.

 

 

 

Have Factory Authorized Service Agent check optional CV regulator board PC2.

 

 

B. Auxiliary Power

 

 

 

Trouble

Remedy

 

 

No output at auxiliary power

Reset receptacle circuit breakers.

receptacles.

 

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings, and optional field current regula-

 

tor board PC1.

 

 

High or low output at auxiliary power

Check engine speed, and adjust if necessary (see Section 7-5).

receptacles.

 

 

 

No or low output at optional auxiliary

Check connections to auxiliary power plant (see Section 6-3).

power plant.

 

 

 

 

Check engine speed, and adjust if necessary (see Section 7-5).

 

 

 

Place A/V Control switch in Panel position, or place switch in Remote position and connect remote con-

 

trol to Remote A/V Control receptacle RC3 (see Sections 4-9and 5-1).

 

 

 

Check fuses F1, F2, and F3 and replace as necessary (see Section 6-3).

 

 

 

Set optional remote control at maximum (see Section 4-9or 4-10).

 

 

 

Place optional Output/Contactor Control switch in On position, or place switch in Remote position and

 

connect remote contactor to optional Remote 14 receptacle RC3 or terminal strip 2T (see Sections 4-10

 

and 4-11).

 

 

 

Place optional CC/CV switch in CC position (see Section 5-3).

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings, and optional field current regula-

 

tor board PC1.

 

 

High output at optional auxiliary power

Check engine speed, and adjust if necessary (see Section 7-5).

plant.

 

 

 

 

Have Factory Authorized Service Agent check optional field current regulator board PC1.

 

 

C. Engine

 

 

 

Trouble

Remedy

 

 

Engine does not start.

Check fuel level (see Section 4-5).

 

 

 

Open fuel valve (see Section 4-5).

 

 

 

Check battery and replace if necessary.

 

 

 

Check blower fan V-belt according to engine manual. Safety shutdown stops engine if belt is broken

 

or loose (see Section 7-8).

 

 

 

Check engine Start button and replace if necessary.

 

 

 

Check engine charging system according to engine manual.

 

 

 

See engine manual.

 

 

Engine suddenly stops.

Check blower fan V-belt according to engine manual. Safety shutdown stops engine if belt is broken

 

or loose (see Section 7-8).

 

 

 

See engine manual.

 

 

Battery discharges between uses.

Clean top of battery with baking soda and water solution; rinse with clear water.

 

 

 

Recharge or replace battery if necessary.

 

 