Miller Electric PipePro Dual manual Lower Display, Setup Push Button

Models: PipePro Dual

1 48
Download 48 pages 56.03 Kb
Page 28
Image 28

6-8. Lower Display

1

 

4

 

Wire Speed

Amps

5

3

2

1 Lower Display

The lower display shows wire speed or amperage.

2 Lower Display Push Button

Press button to choose between wire speed or amperage functions.

3 Lower Display Push Button LED

The lower display push button LED illuminates to indicate that wire feed speed can be ad- justed with the Adjust control.

4Wire Speed LED

5Amps LED

The LEDs below the display illuminate to indi-

cate which value is being shown.

At idle, the wire speed for the active welding sequence may be adjusted or the amperage of the previous weld may be displayed.

If the unit is in a welding state that does not involve feeding wire, such as pre−flow or post−flow, the unit displays the weld se- quence wire speed; otherwise, the wire speed of the active sequence segment of the weld program (run−in, start, weld, crater, etc.), is displayed.

Adjusting wire speed while in a welding state will modify the weld segment of the weld pro- gram. Wire speed for other segments of the weld program can only be modified via the Sequence menu.

When the unit is displaying amperage, the Amps LED illuminates. While in a welding state, the actual weld current is shown. While idle, the amperage at the end of the previous welding state is shown.

Amperage values of less than 5 Amps are displayed as “−−−−”.

6-9. Setup Push Button

3

4 Trigger Hold

Dual Schedule

1

Setup

2

1 Setup Push Button

Press button to choose between trigger hold or dual schedule functions.

2Setup Push Button LED

3Trigger Hold LED

4Dual Schedule LED

When the Setup button is pressed, the Set- up push button LED flashes and the Trigger Hold LED flashes.

Trigger hold is a per program setting.

The flashing LED indicates that the unit is in the trigger hold display mode. In this mode the upper display indicates HOLD and the lower display indicates the trigger hold sta-

tus On/Off. Use the Adjust control to change the trigger hold status or press the lower dis- play push button. If trigger hold is turned On, the trigger hold LED illuminates and stays On.

When trigger hold is On, the user must press and hold the trigger for a predefined amount of time (the trigger hold delay time− see Section 6-12), then release it for the trig- ger hold function to be active. To shut off the weld when trigger hold is On, the user must press and release the trigger.

If a weld time is programmed, trigger hold is disabled.

Dual Schedule is a per program pair setting (1,2) (3,4) (5,6) (7,8).

When the Setup button is pressed a second time, the dual schedule LED flashes. In this mode the upper display indicates DUAL and the lower display indicates dual schedule status On/Off. Use the Adjust control to change the dual schedule status if desired.

Pressing the Setup button again exits the Setup mode. The dual schedule LED stops flashing to indicate the dual schedule status is Off, or remains on if dual schedule was enabled.

While in the Setup mode, if the trigger is acti- vated, Setup mode is terminated.

Dual schedule and trigger select cannot be used concurrently. See Section 6-12for Trigger Program Select.

OM-230 009 Page 24

Page 28
Image 28
Miller Electric PipePro Dual manual Lower Display, Setup Push Button