6-10. Adjust Control

1 Adjust Control

The Adjust control is used to change various parameters.

1

Adjust

6-11. Sequence Push Button

 

 

 

3

Start

 

 

 

Crater

 

 

 

 

 

Weld

 

 

Pre/Postflow

Start

Crater

 

Time

 

 

Time

Time

 

 

 

 

 

2

 

 

 

 

Preflow

 

Postflow

 

 

Time

 

 

 

 

Time

 

 

1

 

 

Sequence

Welding Sequence Diagram

 

 

 

 

1Sequence Push Button

2Sequence Push Button LED

3Welding Sequence LEDs

.For more information on Setting Sequence Parameters see Section 7-1.

The Sequence push button allows the selection of welding sequences. Five weld- ing sequences are available. The default sequence is the Weld sequence. The Weld sequence is active on power up. Three welding sequence LEDs are located above the Sequence push button: Start, Crater, and Preflow/Postflow. The applicable LED illuminates to indicate which welding se- quence is active.

The LED illuminates to indicate that a weld- ing sequence display mode other than Weld is active. Welding sequences other than Weld must be set prior to initiating the arc. When the unit enters a welding state, all se- quence display modes are terminated and

the weld display mode is activated.

If zero time is programmed for a timed se- quence except for Weld, that sequence will be skipped.

In the weld sequence display mode, the Se- quence push button LED is Off. When the Sequence push button is pressed, the Se- quence push button flashes and the Start LEDs flash. In this condition, the unit is in the Start sequence display mode, and Start se- quence parameters are displayed (see Sec- tion 7-1).

When the Sequence push button is pressed a second time, the Crater sequence LED flashes. The Sequence push button LED re- mains flashing. In this condition, the unit is in the Crater sequence display mode, and Crater sequence parameters are displayed.

When the Sequence push button is pressed a third time, the Preflow/Postflow sequence LED flashes. The Sequence push button LED remains flashing. In the Preflow display mode the upper display shows the preflow time and the lower display indicates the ab- breviation PRE, to inform the operator that preflow time is displayed. If the upper dis- play push button is pressed, the Adjust con- trol can be used to adjust preflow.

If the lower display push button is pressed, the Adjust control can be used to select be- tween preflow (PRE) and postflow (POST). When POST is selected, the upper display can be used to specify postflow time.

When the Sequence push button is pressed a fourth time, the unit returns to the welding sequence display mode.

OM-230 009 Page 25

Page 29
Image 29
Miller Electric PipePro Dual manual Adjust Control, Sequence Push Button, Start Crater Time, Welding Sequence Diagram