6-13. Remote-14 Receptacle Information

 

 

1

Remote Switch

 

 

2

Remote-14 Receptacle

 

 

If the remote switch is set to MIG,

 

 

the feeder operates normally. A re-

 

 

mote control may be left attached

 

 

while the remote switch is in the

 

 

MIG mode, as the remote has no af-

 

 

fect on the operation of the wire

 

 

feeder.

 

 

If the remote switch is set to Stick/

 

 

TIG, the feeder controls and meter

 

 

displays are disabled, allowing con-

 

 

trol from a standard remote control.

 

 

When a remote control is con-

 

 

nected to the remote-14 receptacle,

 

 

the PipePro 450 RFC will automati-

 

 

cally adjust output control in a pri-

 

 

mary/secondary configuration, but

 

 

the power source must be set for

 

 

remote operation (see the PipePro

 

 

450 RFC Owner’s Manual for infor-

 

 

mation).

 

 

In this configuration, the Amp Ad-

 

 

just control on the PipePro 450 RFC

 

 

power source becomes the prima-

 

 

ry, and sets the maximum amper-

 

 

age output of the unit. The remote

 

 

control becomes the secondary,

 

 

and provides an amperage range

 

 

adjustment of 0 to 100% of what is

 

 

set on the Amp Adjust control on the

 

 

power source.

1

2

. When in Stick/Tig mode, re-

 

 

 

 

mote program select is still

 

 

 

functional from the feeder.

 

 

!

Do not connect a Stick elec-

 

 

 

trode holder and a MIG gun

 

 

 

to the same output terminal

 

 

 

at the same time, as both

 

 

 

will be live when the contac-

tor is on. An external polar- ity reversing isolation con- trol should be used to iso- late the outputs.

804 667-B