NOTE: Electrical data is for outdoor unit only.

Indoor units

 

 

Heating capacity (kW)

 

Outdoor unit

Current

Power

 

 

 

 

 

 

power consumption

(A)

factor

combination

Unit A

Unit B

Unit C

Unit D

 

Total

 

(kW)

220V

240V

(%)

 

 

 

 

 

 

 

07

3.2

-

-

-

 

3.2

1.13

5.71

5.23

90

 

(0.9-4.1)

(0.27-1.60)

 

 

 

 

 

 

 

 

 

09

4.0

-

-

-

 

4.0

1.32

6.67

6.11

90

 

(0.9-4.8)

(0.27-1.70)

 

 

 

 

 

 

 

 

 

12

6.0

-

-

-

 

6.0

1.91

9.65

8.84

90

 

(0.9-7.2)

(0.27-2.57)

 

 

 

 

 

 

 

 

 

18

7.1

-

-

-

 

7.1

2.30

11.62

10.65

90

 

(0.9-7.8)

(0.27-2.83)

 

 

 

 

 

 

 

 

 

07+07

3.2

3.2

-

-

 

6.4

1.93

9.75

8.94

90

 

(1.8-7.2)

(0.48-2.30)

 

 

 

 

 

 

 

 

 

07+09

3.2

4.0

-

-

 

7.2

2.05

10.35

9.49

90

 

(1.8-8.7)

(0.48-2.68)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+12

3.2

5.4

-

-

 

8.6

2.55

12.88

11.81

90

 

(1.8-10.6)

(0.48-3.80)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+18

2.8

6.2

-

-

 

9.0

2.68

13.54

12.41

90

 

(1.8-10.9)

(0.48-3.89)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09+09

4.0

4.0

-

-

 

8.0

2.35

11.87

10.88

90

 

(1.8-10.1)

(0.48-3.56)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09+12

3.5

5.3

-

-

 

8.8

2.62

13.23

12.13

90

 

(1.8-10.8)

(0.48-3.86)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09+18

3.35

5.95

-

-

 

9.3

2.78

14.04

12.87

90

 

(1.8-11.2)

(0.48-3.98)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12+12

4.65

4.65

-

-

 

9.3

2.78

14.04

12.87

90

 

(1.8-11.2)

(0.48-3.98)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12+18

4.3

5.0

-

-

 

9.3

2.78

14.04

12.87

90

 

(1.8-11.2)

(0.48-3.98)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18+18

4.65

4.65

-

-

 

9.3

2.78

14.04

12.87

90

 

(1.8-11.2)

(0.48-3.98)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+07+07

2.87

2.87

2.87

-

 

8.6

2.42

12.22

11.20

90

 

(2.1-10.6)

(0.52-3.00)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+07+09

2.75

2.75

3.5

-

 

9.0

2.50

12.63

11.57

90

 

(2.1-11.1)

(0.52-3.30)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+07+12

2.4

2.4

4.5

-

 

9.3

2.78

14.04

12.87

90

 

(2.1-11.6)

(0.52-3.50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+07+18

2.2

2.2

4.9

-

 

9.3

2.78

14.04

12.87

90

 

(2.1-11.6)

(0.52-3.50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+09+09

2.7

3.3

3.3

-

 

9.3

2.78

14.04

12.87

90

 

(2.1-11.6)

(0.52-3.50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+09+12

2.25

2.8

4.25

-

 

9.3

2.78

14.04

12.87

90

 

(2.1-11.6)

(0.52-3.50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+09+18

2.1

2.6

4.6

-

 

9.3

2.78

14.04

12.87

90

 

(2.1-11.6)

(0.52-3.50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+12+12

2.0

3.65

3.65

-

 

9.3

2.78

14.04

12.87

90

 

(2.1-11.6)

(0.52-3.50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+12+18

1.85

3.4

4.05

-

 

9.3

2.78

14.04

12.87

90

 

(2.1-11.6)

(0.52-3.50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

07+18+18

1.7

3.8

3.8

-

 

9.3

2.78

14.04

12.87

90

 

(2.1-11.6)

(0.52-3.50)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: SLH-1AR is equivalent to class 09 (9000BTU).

MCFH-13NV, SEH-1.6AR, SLH-1.6AR is equivalent to class 12 (12000BTU).

MCFH-18NV, SEH-2AR,SLH-2AR is equivalent to class 18 (18000BTU).