5
SPECIFICATION
Outdoor model
Outdoor unit power supply
Indoor units number
Indoor units total capacity (Connectable)
System | indoor units total capacity (Simultaneous operation) | |||
Piping total length |
| |||
|
| |||
| Connecting pipe length |
| ||
| Height difference (Indoor ~ Outdoor) | |||
| Height difference (Indoor ~ Indoor) |
| ||
Capacity | Function |
| K /h | |
Outdoor air flow | ||||
| Capacity |
| kW | |
| Dehumidification | R/h | ||
| Power outlet |
| A | |
| Running current | A | ||
Electrical data | Power input |
| W | |
Auxiliary heater | A(kW) | |||
| ||||
| Crankcase heater | W | ||
| Power factor |
| % | |
| Starting current | A | ||
| Compressor motor current | A | ||
| Fan motor current | A | ||
Coefficient of performance(C.O.P) |
| |||
Compressor | Model |
|
| |
Output |
| W | ||
|
| |||
| Winding |
| " | |
| resistance(at20:) | |||
Fan motor | Model |
| ||
Winding |
| " | ||
| resistance(at20:) |
| ||
| Dimensions WOHOD | mm | ||
| Weight |
| kg | |
| Sound level (Hi) | dB | ||
Special remarks | Fan speed (Hi) | rpm | ||
Fan speed regulator |
| |||
|
| |||
| Refrigerant filling | kg | ||
| ||||
|
| |||
| Refrigerating oil (Model) | cc | ||
| Thermistor | RT61 | k" | |
| Thermistor | RT62 | k" | |
| Thermistor | RT63 | k" | |
| Thermistor | RT65 | k" | |
| Thermistor | RT66,67 | k" | |
| Thermistor | RT68,69 | k" | |
|
|
|
✽1 Electrical data is for only outdoor unit. |
|
|
TEST CONDITIONS COOLING INDOOR | DB27.0°C | WB19.0°C |
OUTDOOR DB35.0°C | WB24.0°C | |
HEATING INDOOR | DB20.0°C |
|
OUTDOOR DB 7.0°C | WB 6.0°C |
8
MXZ-32SV - E1 , MXZ-32SV - E2
Single phase
2 to 4
Total model name 42
Total model name 42
Max. 60
Max. 25
| 10 |
| 10 |
Cooling | Heating |
8.0 (0.9~9.0) | 9.3 (0.9~11.6) |
— | — |
25
2980(260~4270) 2780(270~3500)
—
—
90.0
0.6
2.683.35
2100
RA6V60-BA
900o900o320 (+35)
79
3
3.9
870
13.4(at 100:) 10.0 (at 25:) 17.0 (at 50:) 10.0 (at 25:) 10.0 (at 25:) 10.0 (at 25:)