Mitsubishi Electronics MXZ-32SV Outdoor low pressure and outdoor unit current, Heat operation

Models: MXZ-32SV

1 44
Download 44 pages 62.89 Kb
Page 15
Image 15

10-3-4.Outdoor low pressure and outdoor unit current

1. 07-class unit in single operation

NOTE:The unit of pressure has been changed to MPa on the international system of units(SI unit system). The converted score against the traditional unit system can be gotten according to the formula below.

1(MPa • G) =10.2(kgf/f • G)

(1) COOL operation

1Both indoor and outdoor units are under the same temperature/humidity condition.

Dry-bulb temperature(°C)

Relative humidity(%)

20

50

25

60

30

70

2Air flow speed : HI

3Inverter output frequency : 33Hz

<How to work fixed-frequency operation>

1.Set emergency switch to COOL or HEAT.The switch is locat- ed on indoor unit.

2.Press emergency run ON/OFF button. 3.Compressor starts running at rated frequency.

4.Indoor fan runs at HI speed and continues for 30 minutes. 5.To cancel this operation,press emergency run ON/OFF button

or any button on remote controller.

(kgf/F•Gauge) (MPa•Gauge)

Outdoor low pressure

8

7

6

5

4

3

2

0.8

 

 

 

0.7

 

 

 

0.6

 

33Hz

 

 

 

 

0.5

 

 

 

0.4

 

 

 

0.3

 

 

 

0.2

 

35

(;)

15

25

20

30

(%)

Ambient temperature(:)/ Ambient humidity(%)

Outdoor unit current (A)

9

 

 

 

8

 

 

 

7

 

 

 

6

 

 

 

 

 

33Hz

 

5

 

 

 

4

 

 

 

3

 

 

(;)

15 20

25

30 35

 

 

 

(%)

Ambient temperature(:)/ Ambient humidity(%)

(2)HEAT operation

Indoor DB(°C) 20.0

WB(°C) 14.5

Outdoor

DB(°C)

2

7

15

20.0

WB(°C)

1

6

12

14.5

Set air flow to Hi speed.

Inverter output frequency is 45Hz.

Outdoor unit current (A)

10

9

8

7

6

5

4

45Hz

0

5

10

15

20

25

Ambient temperature(:)

15

Page 15
Image 15