Mitsumi electronic PKA-A18HA4 Error Code Abnormal point and detection method, Cause, operating

Models: PKA-A18HA4 PKA-A12HA4

1 36
Download 36 pages 12.47 Kb
Page 17
Image 17
Error Code Abnormal point and detection method

Error Code Abnormal point and detection method

Cause

Countermeasure

 

Freezing/overheating protection is

(Cooling or drying mode)

(Cooling or drying mode)

 

operating

Clogged filter (reduced airflow)

Check clogs of the filter.

 

Freezing protection (Cooling mode)

Short cycle of air path

Remove blockage.

 

The unit is in 6-minute resume prevention

Low load (low temperature)

 

 

mode if pipe <liquid or condenser/evapo-

operation out of the tolerance

 

 

rator> temperature stays under

 

 

range

 

 

the compressor started. Abnormal if it

Defective indoor fan motor

Refer to 9-6.

 

• Fan motor is defective.

 

 

 

 

 

again within 16 minutes after 6-minute

• Indoor controller board is defec-

 

 

resume prevention mode.

tive.

Check outdoor fan motor.

 

 

Defective outdoor fan control

 

 

Overcharge of refrigerant

Check operating condition of refrigerant

 

 

Defective refrigerant circuit

circuit.

 

 

(clogs)

 

 

Overheating protection (Heating mode)

(Heating mode)

(Heating mode)

 

Clogged filter (reduced airflow)

Check clogs of the filter.

 

The units is in 6-minute resume

 

Short cycle of air path

Remove blockage.

 

prevention mode if pipe <liquid or

 

Overload (high temperature)

 

P6

condenser/evaporator> temperature is

 

operation out of the tolerance

 

detected as over 70°C[158°F] after the

 

 

range

 

 

compressor started. Abnormal if the

 

 

Defective indoor fan motor

Refer to 9-6.

 

temperature of over 70°C[158°F] is

 

• Fan motor is defective.

 

 

detected again within 10 minutes after

 

 

• Indoor controller board is defec-

 

 

6 minute resume prevention mode.

 

 

tive.

 

 

 

Check outdoor fan motor.

 

 

Defective outdoor fan control

 

 

Overcharge of refrigerant

~ Check operating condition of refrigerant

 

 

Defective refrigerant circuit

circuit.

 

 

(clogs)

 

 

 

Bypass circuit of outdoor unit

 

 

 

is defective.

 

 

Pipe temperature

 

Slight temperature difference

~ Check pipe <liquid or condenser/evap-

 

 

<Cooling mode>

 

between indoor room

orator> temperature with room tempera-

 

Detected as abnormal when the pipe tem-

temperature and pipe <liquid

ture display on remote controller and

 

 

perature is not in the cooling range 3 min-

or condenser/evaporator>

outdoor controller circuit board.

 

 

utes after compressor start and 6 minutes

temperature thermistor

Pipe <liquid or condenser/evaporator>

 

after the liquid or condenser/evaporator pipe

• Shortage of refrigerant

temperature display is indicated by set-

 

is out of cooling range.

 

• Disconnected holder of pipe

ting SW2 of outdoor controller circuit

 

 

Note 1) It takes at least 9 minutes to detect.

<liquid or condenser/

board as follows.

 

 

Note 2) Abnormality P8 is not detected in

evaporator> thermistor

 

)

 

drying mode.

 

• Defective refrigerant circuit

Conduct temperature check with outdoor

 

Cooling range : -

(TH-TH1)

Converse connection of

controller circuit board after connecting

 

TH: Lower temperature between liquid pipe

extension pipe (on plural units

(‘A-Control Service Tool(PAC-SK52ST)’.

 

temperature (TH2) and condenser/

connection)

 

 

 

evaporator temperature (TH5)

Converse wiring of indoor/

Check converse connection of extension

 

TH1: Intake temperature

 

outdoor unit connecting wire

pipe or converse wiring of indoor/outdoor

P8

<Heating mode>

 

(on plural units connection)

unit connecting wire.

 

 

Defective detection of indoor

 

 

 

When 10 seconds have passed after the

room temperature and pipe

 

 

 

compressor starts operation and the hot

<condenser/evaporator>

 

 

 

adjustment mode has finished, the unit is

temperature thermistor

 

 

 

detected as abnormal when condenser/

Stop valve is not opened

 

 

 

evaporator pipe temperature is not in heat-

completely.

 

 

 

ing range within 20 minutes.

 

 

 

 

 

Note 3) It takes at least 27 minutes to

 

 

 

 

detect abnormality.

 

 

 

 

 

Note 4) It excludes the period of defrosting

 

 

 

 

(Detection restarts when defrosting

 

 

 

 

mode is over)

 

 

 

 

 

Heating range :

(TH5-TH1)

 

 

 

17

Page 17
Image 17