VENT CONFIGURATIONS

VENT INSTALLATION

VENT CONFIGURATIONS

 

Termination Kit

 

490 unit - part # AI42TK43A

Exhaust

380 unit - part #AI31TK33A

 

Inlet

 

4" (100mm) or 3" (75mm)

 

Exhaust UL 1777 Gas Liner

 

3" (75mm) Inlet

Recommended block-off plate (non-combustible metal). Prevents

odors from chimney Figure 8 - Inlet and Exhaust Reline entering room. Figure 9 - Exhaust Only RelineManual backgroundManual backgroundManual background

Exhaust

Any cracks or damage inside chimney must be repaired.

The block-off plate (AI42AK43 or AI31AK33) must seal intake to the chimney space so that air is drawn down chimney for combustion air.

 

Block-off Plate

 

- (AI42AK43 or

 

AI31AK331)

 

non-combustible

 

materials

UL-127,

 

Solid Fuel

Inlet

Z.C. firebox

 

 

Masonry

 

Fireplace

Figure 8 - Inlet and Exhaust Reline

Figure 9 - Exhaust Only Reline

NOTE: You may use either reline configuration with a masonry or zero-clearance fireplace.

57D0016

15

Page 15
Image 15
Monessen Hearth IDV380PVC, IDV490NVC Vent Configurations, Vent Installation, Inlet and Exhaust Reline, Exhaust Only Reline

FAQ

What is a termination kit?

A termination kit is a necessary component for properly venting the fireplace exhaust.

What materials should the block-off plate be made of?

The block-off plate should be made of non-combustible materials, such as solid fuel inlet or Z.C. firebox.

Can I use either reline configuration with a masonry or zero-clearance fireplace?

Yes, you may use either reline configuration with a masonry or zero-clearance fireplace.