Monessen Hearth IDV490NVC Electrical Installation, Electrical Wiring, Remote Wall Mounted Switch

Models: IDV380NVC IDV490NVC IDV380PVC IDV490PVC

1 40
Download 40 pages 49.26 Kb
Page 20
Image 20
ELECTRICAL INSTALLATION

ELECTRICAL INSTALLATION

ELECTRICAL WIRING

This insert will work without any electrical supply. Electricity is only needed to operate blower.

CAUTION WARNINGELECTRICAL WIRING

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city, and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code ANSI/ NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1.

Label all wires before disconnecting when servicing controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

REMOTE WALL MOUNTED SWITCH

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. See Figure 17.

NOTE: Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.

�������

�������������

����������

 

 

 

��������������

��������������

 

 

 

 

 

������

 

 

 

ON

OFF

PILOT

HI

 

 

OFF

ON

TH

 

 

 

 

TP REMOTE WALL MOUNTED SWITCHManual backgroundManual background

TH/TP

���������

�����

Optional

15’ Wall Switch

Manual background ON

Manual backgroundOFF

Optional

Remote Control

Manual background ON

Manual backgroundOFF

Figure 17 - Wiring Diagram for Wall Switch

20

57D0016

Page 20
Image 20
Monessen Hearth IDV490NVC, IDV490PVC, IDV380NVC manual Electrical Installation, Electrical Wiring, Remote Wall Mounted Switch

FAQ

Do I need electricity for the indoor fireplace to work?

No, the fireplace will work without any electrical supply, but electricity is needed to operate the blower.

Can I use a remote wall switch with this fireplace?

Yes, a remote wall switch and up to 15 feet of 18 Ga. wire may be used with this appliance.

What should I do if I encounter wiring errors during installation?

Wiring errors can cause improper and dangerous operation. It is important to verify proper operation after addressing any wiring errors.