Monessen Hearth IDV380PVC manual Glass Replacement, Always use gloves when handling broken glass

Models: IDV380NVC IDV490NVC IDV380PVC IDV490PVC

1 40
Download 40 pages 49.26 Kb
Page 31
Image 31
GLASS REPLACEMENT

GLASS REPLACEMENT

CAUTION

Always use gloves when handling broken glass.

WARNING

Make sure the glass panel edges do not touch any metal parts during thermal expansion.

1.Put on gloves. Remove glass frame from insert by releasing two latches on bottom of insert and lifting the door up and off the unit. See Figure 40.

2.Carefully remove broken glass.

3.Slide new glass frame back down onto insert and fasten two latches. See Figure 40.

NOTE: Use only original replacement parts.

Glass

Frame

Latches

Figure 40 - Removing Door

57D0016