LEAK TESTING (continued)

OPERATING INSTRUCTIONS

LIGHTING PILOT FOR THE FIRST TIME

LEAK TESTING (continued)

 

 

WARNING

If using a soap and water

You may check for gas leaks with the following methods only:

 

 

solution to test for leaks,

Soap and water solution

 

 

 

 

 

 

DO NOT spray solution onto

An approved leak testing spray

 

 

 

control body.

Electronic sniffer

 

 

 

 

 

 

 

 

Check for gas leaks in each of the following locations:

 

 

 

• Pipe from the gas supply line connection to the gas valve

 

 

Burner thread inlet

Field made joints

Pilot

Factory made joints

Each joint or connection

All joints on valve and control body

NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.

LIGHTING PILOT

WARNING

The control has an interlock device that does not allow the lighting of the insert up to the moment the safety device of the flame has not interrupted the gas flow. After that period of time (when the magnet is closed), it is possible to start the lighting operation.

The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury.

1.Depress and turn knob counterclockwise If using a soap and water to pilot position.

2.Push pilot knob in and hold in while pressing piezo ignitor several times until pilot ignites. Continued to hold pilot knob in for several seconds after ignition. Release and check that pilot continues to burn.

If the pilot does not stay lit, repeat steps 1 and 2.

WARNING

If the knob does not “pop” out to

 

 

its original position when released,

 

turn off gas to appliance and contact

 

qualified service technician.

 

 

 

O

 

T

N

 

 

 

 

O

 

 

 

L

 

 

 

I

 

 

 

P

 

 

 

 

F

 

 

P

F

 

 

O

 

I

 

 

 

 

L

 

 

 

O

 

 

 

T

Figure 32 - Pilot Position