OPERATING INSTRUCTIONS
LIGHTING PILOT FOR THE FIRST TIME
LEAK TESTING (continued) |
|
| WARNING | If using a soap and water | ||
You may check for gas leaks with the following methods only: | ||||||
| ||||||
| solution to test for leaks, | |||||
• | Soap and water solution |
|
|
| ||
|
|
| DO NOT spray solution onto | |||
• | An approved leak testing spray |
|
|
| control body. | |
• | Electronic sniffer |
|
|
|
| |
|
|
|
| |||
Check for gas leaks in each of the following locations: |
|
|
| |||
• Pipe from the gas supply line connection to the gas valve |
|
| ||||
• | Burner thread inlet | • | Field made joints | |||
• | Pilot | • | Factory made joints | |||
• | Each joint or connection | • | All joints on valve and control body |
NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.
LIGHTING PILOT
WARNING
The control has an interlock device that does not allow the lighting of the insert up to the moment the safety device of the flame has not interrupted the gas flow. After that period of time (when the magnet is closed), it is possible to start the lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury.
1.Depress and turn knob counterclockwise to pilot position.
2.Push pilot knob in and hold in while pressing piezo ignitor several times until pilot ignites. Continued to hold pilot knob in for several seconds after ignition. Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
WARNING | If the knob does not “pop” out to |
| |
| its original position when released, |
| turn off gas to appliance and contact |
| qualified service technician. |
|
|
| O |
| |
T | N |
| |
|
|
| |
O |
|
|
|
L |
|
|
|
I |
|
|
|
P |
|
|
|
| F |
|
|
P | F |
| |
| O |
| |
I |
| ||
|
| ||
| L |
| |
|
| O | |
|
|
| T |
Figure 32 - Pilot Position
28 | 57D0016 |