GENERAL INSTALLATION INFORMATION

GENERAL INSTALLATION INFORMATION

The following factors should be taken into consideration:

This insert should have sufficient access for its safe operation and maintenance.

The flow of combustion and ventilation air must not be obstructed.

Minimum clearances to combustibles, such as mantels, must be maintained. See Figures 3 and 4, pages 9 and 10.

Never obstruct the front opening of the insert.

Do not install in the vicinity where gasoline or other flammable liquids may be stored.

These units can be installed in a bedroom. See National Fuel Gas Code ANSI Z233.1/NFPA 54 (current edition), the Uniform Mechanical Code (current edition), and Local Building Codes for specific installation requirements.

IMPORTANT: Your direct vent insert was designed to be installed in an existing wood burning fireplace. The location and clearances are subject to local building codes.

INSERT APPLICATIONS

Before installing the gas fireplace insert, consider the functioning needs of the fireplace. Confirm the size of the fireplace cavity, the design of the chimney, and the availablility of the gas supply and electricity for the insert fan.

IMPORTANT: Your direct vent insert is designed to be only vented vertically with a minimum height of 10 feet.

When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes applicable to woodburning fireplaces. Consult local authorities having jurisdiction for these clearances. The underside of the mantel will become warm. Use only finishes which are heat resistant and do not discolor.

CLEARANCES

MINIMUM FIREPLACE SIZE/CLEARANCES TO COMBUSTIBLES

WARNING

The dimensions shown in Figures 4 and 5, pages 9 and 10, are minimum clearances to maintain when installing this heater. Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard.

Maintain the following minimum clearances for service and maintenance. See pages 9 and 10.

8

57D0016

Page 8
Image 8
Monessen Hearth IDV490NVC, IDV490PVC, IDV380NVC, IDV380PVC General Installation Information, Insert Applications, Clearances

FAQ

Can I install the fireplace insert in a bedroom?

Yes, these units can be installed in a bedroom according to the National Fuel Gas Code ANSI Z233.1/NFPA 54 current edition, the Uniform Mechanical Code current edition, and Local Building Codes.

What are the minimum clearances for service and maintenance?

The dimensions shown in Figures 4 and 5 on pages 9 and 10 specify the minimum clearances to maintain when installing this heater. Follow these instructions carefully to ensure safe installation.

What are the venting requirements for the direct vent insert?

The direct vent insert is designed to be only vented vertically with a minimum height of 10 feet.