Monessen Hearth IDV490PVC Installation, Insert Clearances, Mantel Clearances, Hearth Requirements

Models: IDV380NVC IDV490NVC IDV380PVC IDV490PVC

1 40
Download 40 pages 49.26 Kb
Page 9
Image 9
INSTALLATION

INSTALLATION

INSERT CLEARANCES

No combustibles (ie: drapes, doors) may be within, or swing within, 36" of the front of the inset.

Figure 3 - Mantel Clearances

8" (203mm)

MANTEL CLEARANCES

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it

does, it is considered a mantel and must meet the mantel requirements shown above.

HEARTH REQUIREMENTS

The insert must be installed on a non-combustible hearth extending a minimum of 12" from the fireplace opening (local codes may require a larger hearth). The hearth must also extend to both sides of the face (see the table on page 7).

57D0016

9

Page 9
Image 9
Monessen Hearth IDV490PVC, IDV490NVC, IDV380NVC Installation, Insert Clearances, Mantel Clearances, Hearth Requirements

FAQ

What are the insert clearances for Monessen Hearth indoor fireplaces?

No combustibles, such as drapes or doors, may be within 36" of the front of the inset.

What are the mantel clearances for Monessen Hearth indoor fireplaces?

The combustible area above the facing must not protrude more than 3/4" from the facing.

What are the hearth requirements for Monessen Hearth indoor fireplaces?

The insert must be installed on a non-combustible hearth extending a minimum of 12" from the replace opening.