LX Series Direct Vent Gas Fireplace | SECURE FIREPLACE to floor or framing |
|
|
The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two
(2)wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side brackets are adjustable from 1/2" to 5/8" to accommodate different thickness of noncombustible material.
Framing
Adjustable
Bracket
Screws
Screws
Figure 6 -
Securing Fireplace to Floor and Framing Studs
Framing
Adjustable
Bracket
Screws
FP2712
NOTE: Do not allow combustibles (drywall) to touch top and side edges of
Do not allow any combustible to overlap the
WARNING
Never obstruct or modify the air inlet or outlet grills (louvers). This may create a fire hazard.
Finishing Material
NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstruction.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating
of Zero) may be used to cover the black surface of the appliance. A 300°F minimum adhesive may be used to attach facing materials to the black surface. If joints between the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material (General Electric RTV103 or equivalent) must be used.
10 | 51D0528 |