Do not use open flame to check for gas

CHECKING GAS PRESSURE and ELECTRICAL INSTALLATION LX Series Direct Vent Gas Fireplace

1.Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the

appliance. Contact your dealer immediately.

2. To ease installation, a 30" (mm) flex line with manual shut-off valve has been provided with on this appli- ance. Install and attach 1/2" gas line onto shut-off valve.

3. After completing gas line connection, purge air from

 

 

gas line and test all gas joints from the gas meter

Pressure

 

to the fireplace for leaks. Use a solution of 50/40

 

Test “IN”

 

water and soap or a gas sniffer.

 

 

 

4. To adjust flame height, turn HI/LO knob to HI to get

Pressure

FP1979

maximum pressure to burner. Turn HI/LO knob to

Test “OUT”

 

LO to get minimum pressure.

 

 

5. To check gas pressures at valve, turn captured

HI/LO Knob

 

screw counter clockwise 2 or 3 turns and then place

Pilot Adjustment Screw

tubing to pressure gauge over test point. Turn unit

 

Figure 35 -

to high. Figure 35. After taking pressure reading,

 

 

Gas Pressure Check at Gas Valve

be sure and turn captured screw clockwise firmly

 

 

to reseal. Do not over torque. Check test points for

WARNING

 

gas leaks.

Do not use open flame to check for gas

 

 

 

leaks.

Electrical Wiring

This fireplace will work without any electrical supply. Elec- tricity is only needed to operate blower.

NOTE: If installed in mobile home, fireplace must be bolted securely to floor.

WARNING

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1.

CAUTION

Label all wires before disconnecting when

 

 

servicing controls. Wiring errors can cause

 

improper and dangerous operation.

 

 

Verify proper operation after servicing.