Monessen Hearth LX32DV cleaning and maintenance, Venting system, Cleaning glass, Firebox Cleaning

Models: LX36DV LX32DV

1 48
Download 48 pages 49.92 Kb
Page 37
Image 37
cleaning and maintenance

cleaning and maintenance

LX Series Direct Vent Gas Fireplace

 

 

WARNING

Turn off gas before servicing fireplace. It

is recommended that a qualified service

 

 

technician perform these check-ups at the

 

beginning of each heating season

 

 

Make sure the gas valve knob is in the “OFF” position. Wait at least five (5) minutes before start-ing maintenance. Fireplace must be cold before starting maintenance.

Venting system

A qualified agency should examine the venting system annually.

Cleaning glass

Clean the ceramic glass periodically. Condensation will sometimes form on the glass during a cold startup. This is normal for all gas fireplaces. This condensation often attracts dust and lint to the surface of the glass. The initial paint curing of the appliance can also leave a slight film on the glass.

Your should clean the glass after the first two weeks of use. After that, you should clean the glass no more than two or three times a season. Use a mild glass cleaner to clean the door.

Do not use abrasive cleaners. They will damage the glass surface.

PILOT AND BURNER FLAMES

Visually check pilot and burner flames periodically. Refer to Figure 54 for typical burner flame. Refer to Figure 55 for typical pilot flame.

FIREBOX CLEANING

1.Carefully remove log set, and embers from combustion chamber.

2.Vacuum burner compartment thoroughly.

3.Vacuum any dust off logs.

4.Remove any lint from main burner and pilot.

5.Carefully replace log set, and embers in their correct positions. Page 28

6.Replace door (if it has been removed).

7.Relight pilot. Page 35

8.Turn on main burner.

 

WARNING

Carefully reassemble and reseal fireplace

 

 

 

 

properly after any cleaning or servicing.

 

 

 

 

CAUTION

Allow glass to cool before cleaning. Do

 

 

 

 

not clean glass when it is hot. Damage

 

 

could occur.

 

 

 

 

WARNING

Make sure clearances to combus-

 

 

 

 

tibles allow room for maintenance

 

 

and service.

 

 

 

Thermocouple

Thermopile

Figure 54 -

FP2721

Typical Pilot Flame

 

Figure 55 -

Typical Burner Flame

Appearance

LG812

51D0528

37

Page 37
Image 37
Monessen Hearth LX32DV cleaning and maintenance, Venting system, Cleaning glass, Pilot And Burner Flames, Firebox Cleaning