Monessen Hearth LX32DV product features, product SPECIFICATIONS, High Elevations, GAS pressures

Models: LX36DV LX32DV

1 48
Download 48 pages 49.92 Kb
Page 5
Image 5
product features

product features

LX Series Direct Vent Gas Fireplace

product SPECIFICATIONS

This appliance has been certified for use with either natural or propane gas. See appropriate data plates.

This appliance is not for use with solid fuels.

The appliance is approved for bedroom or bedsitting room installations.

The appliance must be installed in accordance with local codes if any. If none exist use the current instal- lation code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in Canada.

This appliance is mobile home approved.

The appliance must be properly connected to a vent- ing system.

On/Off/

RS Switch

Off/Pilot/On

Knob

Hi/Lo Knob

Blower Control

Optional Remote

Receiver

FP2710

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certi- fied without deration for elevations up to 4,500 feet (1,370 m) above sea level.

For elevations above 4,500 feet (1,370 m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at eleva- tions above 4,500 feet (1,370 m).

Figure 1 -

LXDV Fireplace Controls

Gas Specifications & ORIFICE SIZE

 

 

Max.Input

Min. Input

Orifice Size

Model

Fuel

BTU/h

BTU/h

Front

Rear

LX32NV

Nat.

36,000

26,000

#46

#43

LX32PV

LP

36,000

22,000

3/64"

#55

LX36NV

Nat.

44,000

30,000

#41

#38

LX36PV

LP

44,000

32,000

#55

#53

 

 

 

 

 

 

GAS pressures

 

Natural

Propane (LP)

Inlet Minimum

4.5” w.c.

11.0” w.c.

Inlet Maximum

10.5” w.c.

13.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

51D0528

Page 5
Image 5
Monessen Hearth LX32DV product features, product SPECIFICATIONS, High Elevations, Gas Specifications & ORIFICE SIZE