venting installation | LX Series Direct Vent Gas Fireplace |
|
|
| WARNING | After conversion to top vent configuration |
|
| |
|
| the 4" (102 mm) flue pipe should be |
|
| concentric within the 6B\," (175 mm) outer |
|
| collar (within 1/4"). |
|
|
|
Optional top vent application
The appliance is shipped as a rear vent unit. If the installa- tion layout requires the unit to be a top vent configuration the appliance can be converted by the following steps.
When removing and refitting the plates and adapter be sure the associated gaskets are undamaged and refitted as required.
1.Remove the eight (8) screws securing the flue pipe adapter to the fireplace body. Figure 7
2.Set the flue pipe adapter aside, complete with the gasket. Do not damage the gaskets as the adapter and gasket must be refitted.
3.Remove the eight (8) screws securing the flue pipe cover to the top of the intake box and remove the cover and gasket. Figure 7
Screws
Flue Pipe
Cover
Flue Cover
Screws
Flue Pipe
FP1992
Figure 8 -
Remove Flue Pipe
Flue Pipe
Screws
FP1991
Flue Pipe
Adapter
Figure 7 -
Remove 16 Screws from Flue Pipe
Adapter and Flue Pipe Cover
4.Remove eight (8) screws securing the flue pipe to the back of the intake box and remove the pipe and gasket. Figure 8
5.Replace flue pipe to top of firebox. Ensure the gasket is in place and undamaged. Secure with eight (8) screws. Figure 9
6.Place the flue pipe cover and gasket removed in step 3 over the flue opening in bottom of the intake box.
Figure 9 - | FP1993 |
Attach Flue Pipe to Top
Vent Configurations
7.Refit the flue pipe adapter and gasket to the top of fire- place. Secure the adapter with eight (8) screws removed in Step 1.