LX Series Direct Vent Gas Fireplace | OPERATING INSTRUCTIONS |
|
|
Lighting burner
main burner switch
The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON” position to light the main burner. Figure 50
Lighting the burner
ON OFF RS
Depress and turn the knob counterclockwise to the “ON” position. Figure
51.It will take less than four (4) seconds for the burner to ignite.
Pilot position
Depress and turn knob to pilot position to keep burner off while maintaining the pilot light. Figure 52
| O |
T | N |
| |
O |
|
L |
|
I |
|
P |
|
| F |
| F |
| O |
PILOT |
Figure 52 -
Pilot Position
to turn off gas
Depress and turn knob clockwise to “OFF” position. Figure 53
Figure 50 - On/Off/RS Switch
N |
|
|
O |
| O |
|
| |
|
| F |
|
| F |
|
| P |
PILOT | ||
T | L |
|
O |
|
|
Figure 51 -
On Position
WARNING
The control is fitted with a safety interlock device which prevents unsafe ignition of the pilot burner after the control knob has been turned to the OFF position. The knob may only be rotated back to the PILOT position after the safety magnet has been released (approximately 60 seconds). You will hear a “click” when the safety magnet releases.
| PI |
| L |
| O |
| T |
F |
|
F |
|
O | O |
| N |
PILOT |
Figure 53 -
Off Position
36 | 51D0528 |