LX Series Direct Vent Gas Fireplace | AIR RESTRICTOR ADJUSTMENT |
|
|
Bend Tabs Up for All Vertical Applications Only
Air Restrictor
Slide Left
and Right
Figure 47 - |
| |
Adjust Baffle on Air Restrictor | Screw | |
Plate | ||
|
The fireplace is equipped with a restrictor plate that is located inside the top chamber of the fireplace. Depending upon the vent configuration, you may be required to adjust the restrictor position
1.Remove glass frame. Refer to Glass Frame Removal, Page 27.
2.Using a Phillips screw driver, loosen the screw that secures the air restrictor. Do not back the screw all the way out.
3.Slide the baffle on top of the restrictor plate such that it blocks a percentage of the grill opening. Refer to the chart for recommended settings.
NOTE: All the settings above are based on the testing at the factory and provided as a guide for startup. On certain applications, adding a restrictor disc will help to achieve flame aesthetics.
FP2719
Venting Height (feet) | % of Grill Opening |
8 to 20 | 100% (Factory Setting) |
20 to 30 | 50% |
30 to 40 | 0% |
|
|
32 | 51D0528 |