Overview2-13
Options and Accessories
The factory ships the BT100 as a fully functional unit, but you must configure it appropriately for the field location requirements. You must install the correct forward equalizer or broadband cable simulator and input pad to place the unit into service. Section 3, “Amplifier Setup” provides information to assist you in this task. Use model
Table
Table
BT100 options and accessories
Model | Description | Function |
Automatic Drive Unit | By monitoring changes in level of the selected pilot carrier, this | |
|
| board automatically controls amplifier output levels that |
|
| change with cable attenuation and hybrid output for the sensed |
|
| temperature. |
QADU* | QAM Automatic Drive Unit | This board automatically controls amplifier output levels that |
|
| change with cable attenuation and hybrid output. The selection |
|
| of a pilot frequency (QAM modulated digital channel) is |
|
| required. |
TDU | Thermal Drive Unit | This board controls amplifier output levels that change with |
|
| cable attenuation for the sensed temperature. |
STARLINE Forward | This 1GHz equalizer compensates for cable properties in 1 dB | |
| Equalizer | increments from 0 dB through 22 dB. You must install the |
|
| appropriate value. |
STARLINE Return | This bandwidth specific equalizer compensates for cable | |
| Equalizer | attenuation in 1 dB increments from 0 dB to 12 dB for |
|
| dB increments for all other splits). You must install the |
|
| appropriate value. |
STARLINE Cable Simulator | This simulator compensates for cable properties. You must | |
|
| install the appropriate value. |
Fixed attenuator | This pad is used to attenuate excessive input signal and can | |
|
| be used to adjust amplifier gain. It is available in 1 dB |
|
| increments from 0 dB to 26 dB. You must install the |
|
| appropriate value. |
Thermal attenuators | This option compensates for gain changes with temperature in | |
|
| the return path. |
Fast Transfer Electronic | This surge arrestor is used for overvoltage protection. | |
| Crowbar |
|
Ingress Control Switch | This option enables remote monitoring, isolation, and reduction | |
|
| of ingress on the return path by providing signal attenuation of |
|
| 6 dB or cutoff of 38 dB typical. The unit is shipped with |
|
| jumpers in these locations. The ICS can be ordered separately |
|
| and customer installed. To control the ICS, you must install the |
|
| LIFELINE status monitor available from AM Networks. |
BT100 Installation and Operation Manual