AC Current
AC Voltage |
| With |
90 VAC | 0.75 A | 0.80 A |
75 VAC | 0.91 A | 0.96 A |
60 VAC | 1.15 A | 1.22 A |
53 VAC | 1.31 A | 1.39 A |
45 VAC | 1.57 A | 1.66 A |
38 VAC | 1.90 A | 2.00 A |
RA-Kit/H Return Amplifier
Parameter | Specification |
Passband | 5 through 40 MHz |
Gain, station (minimum) | 17.5 dB |
Flatness | ±0.75 dB |
Level control | Fixed pads, |
Performance – reference frequency (MHz) | 40 |
At typical output | 35 dBmV, flat |
Channels | 6 NTSC |
Crossmod (worst case) | |
CTB (worst case) | |
CSO (worst case) | |
Noise figure | 12.5 dB |
Power requirements | 24 VDC, 125 mA |
ADU/QADU Automatic Drive Unit
Parameter | Specification |
Pilot channel | See current catalog |
Adjacent channel frequency | ±6 MHz |
Minimum BT100 output at pilot frequency | +36 dBmV |
ALC stiffness | ±0.3 output change for ±3.0 dB input change |
Power requirement | 24 VDC, 75 mA |
BT100 Installation and Operation Manual