Specifications

Specifications are valid over the given bandpass and operating temperature range of 40°F to +140°F (40°C to +60°C). Specifications are stated typical unless otherwise noted, and are subject to change. Refer to the Motorola CHS web site or contact your account representative for the latest specifications.

Model BT100

Specification

Passband

Gain

Full

Operational

Flatness

52 through 1003 MHz Level control, automatic Gain control

Performance - reference frequency (MHz)

At typical output (dBmV)

Channels

Crossmod (worst case)

CTB (worst case)

CSO (worst case)

Noise figure

At 52 MHz

At 1003 MHz Interstage equalizer, BDR-1G Hum modulation

Return loss, input/output

Test points, input/output

Housing dimensions

Weight

Forward Amplifier

52 through 1003 MHz

46 dB (with SFE-*-*)

42 dB (with SFE-*-* and slope reserves)

±0.70 dB maximum

Bode board using ADU/QADU/TDU

Fixed pads, JXP-B

1003/550/52

45/44/37

79 analog/320 MHz digital (suppressed by

6dB) –66 dB –75 dB –71 dB

10 dB (with SFE-1)

10 dB (with SFE-1)

14 ±1 dB –70 dB

16 dB at operational level

20 ±1.0 dB

21.6L × 10.6 W× 7.7 D inches (54.9 × 26.9 × 19.6 cm) 27 pounds (12.25 kg)

BT100 Installation and Operation Manual