Motorola BT100 operation manual Completing the Test Procedures

Models: BT100

1 52
Download 52 pages 62.92 Kb
Page 43
Image 43

4-4

Bench Testing

Example:

11.2dB (measured gain)

+1.0 dB (equalizer insertion loss)

+1.1 dB (power combiner)

+0.0 dB (pads)

+4.6 dB (cable simulator at 40 MHz)

17.9dB (unit gain)

Completing the Test Procedures

The amplifier is now approximately tailored for a specific field location. Additional adjustments after installation are minor in nature. Re-install the fuses removed during testing.

Complete station records by recording pertinent information. Remove test-equipment connections and close the housing following instructions provided in Section 5, “Installation,” Closing the Housing.