Motorola BT100 operation manual Frequency MHz versus Insertion Loss dB, Equalizer, 1003, Value

Models: BT100

1 52
Download 52 pages 62.92 Kb
Page 29
Image 29
Frequency (MHz) versus Insertion Loss (dB)

3-4

Amplifier Setup

Table 3-1 helps you choose the correct equalizers and also lists insertion loss at various frequencies.

Table 3-1

Starline Forward Equalizers — SFE-100-*

 

 

 

 

Frequency (MHz) versus Insertion Loss (dB)

 

 

Equalizer

Equalizer

50

200

300

450

550

650

750

870

1003

Value

Slope

 

 

 

 

 

 

 

 

 

SFE-100-*

 

 

 

 

 

 

 

 

 

 

22

17.1

18.1

13.2

11.0

8.3

6.7

5.3

4.0

2.5

1.0

20

15.5

16.5

12.1

10.1

7.6

6.2

4.9

3.7

2.4

1.0

18

14.0

15.0

11.0

9.2

6.9

5.7

4.5

3.4

2.2

1.0

16

12.4

13.4

9.9

8.2

6.3

5.2

4.1

3.2

2.1

1.0

14

10.9

11.9

8.7

7.3

5.6

4.6

3.7

2.9

2.0

1.0

12

9.3

10.3

7.6

6.4

5.0

4.1

3.3

2.6

1.8

1.0

10

7.8

8.8

6.5

5.5

4.3

3.6

2.9

2.4

1.7

1.0

8

6.2

7.2

5.4

4.6

3.6

3.1

2.6

2.1

1.5

1.0

6

4.7

5.7

4.3

3.7

3.0

2.6

2.2

1.8

1.4

1.0

4

3.1

4.1

3.2

2.8

2.3

2.0

1.8

1.5

1.3

1.0

2

1.6

2.6

2.1

1.9

1.7

1.5

1.4

1.3

1.1

1.0

Figure 3-1 illustrates a graph of the equalizer slope versus equalizer value information presented in Table 3-1. The amount of cable equals the equalizer value.

Figure 3-1

Equalizer slope versus cable

BT100 Installation and Operation Manual

Page 29
Image 29
Motorola BT100 operation manual Frequency MHz versus Insertion Loss dB, Equalizer, 1003, Value