Scanning 2 - 3

Low beep Delete last saved rule. The current rule is left intact.
Low-high-high beeps All rules have been deleted.
Short low-short high-short low-short high
beeps Out of host ADF parameter storage space. See
Default
Parameters on page 5-4
.
ADF Programming Error Indications
Low-high-low-high beeps Out of rule memory. Erase some existing rules, then try to save
rule again. (It is not necessary to re-enter the current rule.)
A Symbol LS3578 scanner was inserted into an STB3478 cradle.
Low-high-low beeps ADF transmit error. Cancel rule entry. Rule entry mode exited
because of an error or the user asked to exit rule entry.
Low-high beeps Entry error, wrong bar code scanned. Re-enter criterion or action.
All previously entered criteria and actions are retained. Criteria or
action list is too long for a rule.
Host Specific
USB Only
Four high beeps The scanner did not complete initialization. Wait several seconds
and scan again.
Short low-short medium-short high
beeps (power-up sequence) The scanner scanned a USB device type. The scanner must
establish communication with the bus before it can operate at the
highest power level.
Short low-short medium-short high
beeps (power-up sequence) occur
more than once
The USB bus may cause power to the scanner to cycle on and off
more than once. This is normal and usually happens when the
host PC cold boots.
RS-232 only
High-high-high-low beeps RS-232 receive error.
High beep A <BEL> character is received and Beep on <BEL> is enabled
(Point-to-Point mode only).
Table 2-1
Sta ndard Beeper Definitions (Continued)
Beeper Sequence Indication