NPort 5110 Series User’s Manual

Web Console Configuration

internal buffer. NPort 5110 transmits data stored in the buffer via TCP/IP, but only if the internal buffer is full or if the Force transmit time interval reaches the time specified under Force transmit timeout.

The optimal Force transmit timeout depends on your application, but it must be at least larger than one character interval within the specified baud rate. For example, assume that the serial port is set to 1200 bps, 8 data bits, 1 stop bit, and no parity. In this case, the total number of bits needed to send a character is 10 bits, and the time required to transfer one character is

( 10 (bits) / 1200 (bits/s) ) * 1000 (ms/s) = 8.3 ms.

Therefore, you should set Force transmit timeout to be larger than 8.3 ms, so in this case, it must be greater than or equal to 10 ms.

If the user wants to send a series of characters in the same packet, the serial device attached to NPort 5110 should send that series of characters during a time interval less than the Force transmit timeout for NPort 5110, and the total length of data must be less than or equal to NPort 5110’s internal buffer size. The serial communication buffer size for NPort 5110 is 1 KB per port.

Destination IP address 1

Setting

 

 

Factory Default

Necessity

IP address range

 

Begin:

Empty

Required

E.g.,

Begin: 192.168.1.1

 

 

 

End:

Empty

 

 

End:

192.168.1.10

 

 

 

 

 

 

 

 

Port:

4001

 

 

 

 

 

Destination IP address 2/3/4

 

 

 

Setting

 

 

Factory Default

Necessity

IP address range

 

Begin:

Empty

Optional

E.g.,

Begin: 192.168.1.11

 

 

 

End:

Empty

 

 

End:

192.168.1.20

 

 

 

 

 

 

 

 

Port:

4001

 

 

 

 

 

 

Local listen port

 

 

 

 

Setting

 

 

Factory Default

Necessity

1 to 65535

 

4001

 

Required

The UDP port that NPort 5110 listens to, and that other devices must use to contact NPort 5110. To avoid conflicts with well known UDP ports, the default is set to 4001.

5-19

Page 41
Image 41
Moxa Technologies 5110 Series user manual Local listen port