EDS-726 Series User’s Manual

Featured Functions

 

 

 

 

 

 

 

 

 

System Event

Warning Relay output is triggered when…

 

 

 

 

Power Transition (OnÆOff)

EDS-726 is powered on.

 

 

 

 

Power Transition (OffÆOn)

EDS-726 is powered down.

 

 

 

 

DI1 (OnÆOff)

Digital Input 1 is triggered by on to off transition

 

 

 

 

DI1 (OffÆOn)

Digital Input 1 is triggered by off to on transition

 

 

 

 

DI2 (OnÆOff)

Digital Input 2 is triggered by on to off transition

 

 

 

 

DI2 (OffÆOn)

Digital Input 2 is triggered by off to on transition

 

 

 

 

 

 

 

 

 

 

Port Event

Warning e-mail is sent when…

 

 

 

 

Link-on

The port is connected to another device.

 

 

 

 

Link-off

The port is disconnected (e.g., the cable is pulled out,

 

 

 

 

or the opposing device shuts down).

 

 

 

 

 

 

 

 

 

Traffic-Overload

The port’s traffic surpasses the Traffic-Threshold for

 

 

 

 

that port (provided this item is Enabled).

 

 

 

 

 

 

 

 

 

Traffic-Threshold (%)

Enter a nonzero number if the port’s Traffic-Overload

 

 

 

 

item is Enabled.

 

 

 

 

 

 

 

 

 

 

A Traffic-Overload warning is sent every

 

 

 

 

Traffic-Duration (sec.)

Traffic-Durationseconds if the average

 

 

 

 

Traffic-Threshold is surpassed during that time

 

 

 

 

 

 

 

 

 

 

period.

 

 

 

 

 

NOTE

The Traffic-Overload,Traffic-Threshold (%), and Traffic-Duration (sec) Port Event items

 

 

are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero

 

 

Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.

 

 

 

 

 

 

Override relay alarm settings

Click the checkbox to override the relay warning setting temporarily. Releasing the relay output will allow administrators to fix any problems with the warning condition.

Relay Alarm List

Use this table to see if any relay alarms have been issued.

3-60

Page 75
Image 75
Moxa Technologies EDS-726 user manual Relay Alarm List, Override relay alarm settings