Moxa Technologies EDS-726 Using Diagnosis, Mirror Port, Output data stream, Bi-directional

Models: EDS-726

1 101
Download 101 pages 17.89 Kb
Page 78
Image 78

EDS-726 Series User’s Manual

Featured Functions

 

Desired IP Address

 

 

 

 

 

 

 

 

 

 

 

 

Setting

 

Description

 

Factory Default

 

 

IP Address

 

Set the desired IP of connected devices.

 

None

 

Using Diagnosis

MOXA EDS-726 provides two important tools for administrators to diagnose network systems.

Mirror Port

The Mirror port function can be used to monitor data being transmitted through a specific port. This is done by setting up another port (the mirror port) to receive the same data being transmitted from, or both to and from, the port under observation. This allows the network administrator to “sniff” the observed port and thus keep tabs on network activity.

Take the following steps to set up the Mirror Port function:

STEP 1

Configure EDS-726’s Mirror Port function from either the Console utility or Web Browser interface. You will need to configure three settings:

Monitored Port Select the port number of the port whose network activity will be monitored.

Mirror Port Select the port number of the port that will be used to monitor the activity of the monitored port.

Watch Direction Select one of the following two watch direction options:

yOutput data stream

Select this option to monitor only those data packets being sent out through EDS-726’s port.

yBi-directional

Select this option to monitor data packets both coming into, and being sent out through, EDS-726’s port.

STEP 2

Be sure to activate your settings before exiting.

When using the Web Browser interface, activate by clicking on the Activate button.

When using the Console utility, activate by first highlighting the Activate menu option, and then press Enter. You should receive the Mirror port settings are now active! (Press any key to continue) message.

3-63

Page 78
Image 78
Moxa Technologies EDS-726 user manual Using Diagnosis, Mirror Port, Output data stream, Bi-directional