EDS-726 Series User’s Manual

Featured Functions

To configure EDS-726 VLANs, use the VLAN Port Setting page to configure the ports.

Port Type

Setting

Description

Factory Default

Access

This port type is used to connect single devices without

 

 

tags.

 

Trunk

Select “Trunk” port type to connect another 802.1Q

Access

 

VLAN aware switch or another LAN that combines

 

 

tagged and/or untagged devices and/or other

 

 

switches/hubs.

 

ATTENTION

For communication redundancy in the VLAN environment, set “Redundant Port,” “Coupling Port,” and “Coupling Control Port” as “Trunk Port,” since these ports act as the “backbone” to transmit all packets of different VLANs to different EDS-726 units.

Management VLAN ID

Setting

Description

Factory Default

VLAN ID

Set the management VLAN of this EDS-726.

1

ranges from

 

 

1 to 4094

 

 

Port PVID

 

 

Setting

Description

Factory Default

VID range from 1

Set the port default VLAN ID for untagged devices that

1

to 4094

connect to the port.

 

Port Fixed VLAN List (Tagged)

 

 

 

 

Setting

Description

Factory Default

VID range from 1

This field will be active only when selecting the “Trunk”

None

to 4094

port type. Set the other VLAN ID for tagged devices that

 

 

connect to the “Trunk” port. Use commas to separate

 

 

different VIDs.

 

Port Forbidden VLAN List

 

 

 

 

Setting

Description

Factory Default

VID range from 1

This field will be active only when selecting the “Trunk”

None

to 4094

port type. Set the VLAN IDs that will not be supported

 

 

by this trunk port. Use commas to separate different

 

 

VIDs.

 

3-41

Page 56
Image 56
Moxa Technologies EDS-726 user manual Management Vlan ID, Port Pvid, Port Fixed Vlan List Tagged, Port Forbidden Vlan List