Moxa Technologies EDS-726 user manual Event Types, System Event, Port Event

Models: EDS-726

1 101
Download 101 pages 17.89 Kb
Page 72
Image 72

EDS-726 Series User’s Manual

Featured Functions

Event Types

Event Types can be divided into two basic groups: System Events and Port Events. System Events are related to the overall function of the switch, whereas Port Events are related to the activity of a specific port.

System Event

Warning e-mail is sent when…

Switch Cold Start

Power is cut off and then reconnected.

Switch Warm Start

EDS-726 is rebooted, such as when network

 

parameters are changed (IP address, subnet mask,

 

etc.).

Power Transition (OnÆOff)

EDS-726 is powered down.

Power Transition (OffÆOn)

EDS-726 is powered up.

DI1 (OnÆOff)

Digital Input 1 is triggered by on to off transition

DI1 (OffÆOn)

Digital Input 1 is triggered by off to on transition

DI2 (OnÆOff)

Digital Input 2 is triggered by on to off transition

DI2 (OffÆOn)

Digital Input 2 is triggered by off to on transition

Configuration Change Activated

Any configuration item has been changed.

Comm. Redundancy Topology

If any Spanning Tree Protocol switches have changed

Changed

their position (applies only to the root of the tree).

 

If the Master of the Turbo Ring has changed or the

 

backup path is activated.

Authentication Failure

An incorrect password is entered.

Port Event

Warning e-mail is sent when…

Link-on

The port is connected to another device.

Link-off

The port is disconnected (e.g., the cable is pulled out,

or the opposing device shuts down).

 

Traffic-Overload

The port’s traffic surpasses the Traffic-Threshold for

that port (provided this item is Enabled).

 

Traffic-Threshold (%)

Enter a nonzero number if the port’s Traffic-Overload

item is Enabled.

 

 

A Traffic-Overload warning is sent every

Traffic-Duration (sec.)

Traffic-Durationseconds if the average

Traffic-Threshold is surpassed during that time

 

 

period.

NOTE

The Traffic-Overload,Traffic-Threshold (%), and Traffic-Duration (sec.) Port Event items

 

are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero

 

Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds.

 

 

 

 

NOTE

Warning e-mail messages will have sender given in the form:

 

Moxa_EtherDevice_Switch_0001@Switch_Location

 

where Moxa_EtherDevice_Switch is the default Switch Name, 0001 is EDS-726’s serial number,

 

and Switch_Location is the default Server Location.

 

Refer to the Basic Settings section to see how to modify Switch Name and Switch Location.

 

 

3-57

Page 72
Image 72
Moxa Technologies EDS-726 user manual Event Types, System Event, Port Event, MoxaEtherDeviceSwitch0001@SwitchLocation