Moyer Diebel MH-60M3, MH-6NM3 305mm, INSTALLATION Cont, Plumbing Connections, Water Connections

Models: MH-60M3 MH-6LM3 MH-6NM3

1 72
Download 72 pages 55.49 Kb
Page 14
Image 14
INSTALLATION (Cont.)

INSTALLATION

INSTALLATION (Cont.)

 

Plumbing Connections

 

NOTE:

 

Plumbing connections must comply with

 

all applicable sanitary and plumbing

 

codes.

 

Water Connections

12"

 

1. All MH series dishwashers require a single,

[305mm]

 

hot water supply.

 

 

FLOOR

The hot water connection to all MH

 

series dishwashers is 3/4" NPT.

 

The connection is made from

 

underneath the dishwasher.

 

 

Figure 7

 

Hot Water Connection

The following minimum water

(MH-60 Only)

3/4" NPT

temperatures are recommended:

 

MH-60 with built-in 40° rise electric booster (Minimum 140°F/60°C) (Min./Max. flow pressure

20-22 PSI/138-151.8 kPa)

MH-60 with built-in 70° rise electric booster (Minimum 110°F/43°C) (Min./Max. flow pressure

20-22 PSI/138-151.8 kPa)

MH-6N without built-in booster (Minimum 180°F/70°C) (Min./Max. flow pressure 20-22 PSI/138-151.8 kPa)

MH-6L low temperature (Minimum 120°F/49°C- 140°F/60°C Optimum)

(Min./Max. flow pressure 20-22 PSI/138-151.8 kPa)

Refer to Figs. 7 and 8

12"

[305mm]

FLOOR

Figure 8

Hot Water Connection

(MH-6N, MH-6L Only)

3/4" NPT

12