Moyer Diebel MH-60M3 Basic Service, Electrical Service, Troubleshooting, Schematics, Tools

Models: MH-60M3 MH-6LM3 MH-6NM3

1 72
Download 72 pages 55.49 Kb
Page 29
Image 29
BASIC SERVICE

BASIC SERVICE

BASIC SERVICE

This Basic Service section does not cover all possible repair procedures. If you require additional service support, you may call your local service company or:

Moyer Diebel National Service

USA: 1-800-858-4477

Canada: 1-800-263-5798

Please have the Model and Serial Number of the machine ready when you call.

ELECTRICAL SERVICE

Moyer Diebel National ServiceNOTE:

DO NOT USE CHASSIS GROUND WHEN PERFORMING VOLTAGE CHECKS.

Doing so will result in false and inaccurate readings.

PERFORM VOLTAGE CHECKS BY READING FROM THE HOT SIDE OF THE LINE AND NEUTRAL (any #2 or white wire).

WARNING:

! USE EXTREME CAUTION when performing tests on energized circuits.

WARNING:

! When repairing a circuit, disconnect the power at the main service disconnect switch and place a tag at the disconnect switch to indicate that work is being performed on the circuit.

Troubleshooting

Schematics

Moyer Diebel places an electrical schematic in the control cabinet of every machine before it is shipped. Schematics are included at the back of this manual as well. Be aware that these schemat- ics include options that may not apply to your machine. Options are enclosed in dashed lines with the words (IF USED) next to them on the schematic. Disregard any options that appear on the schematics which are not a part of your machine.

Tools

All electrical repairs can be made with:

Standard set of hand tools Volt/Ohm Meter (VOM) Clip-on AC current tester

Circuit Tests

Use a clip-on AC current tester to check the motors and electric heaters. Use a VOM to test line voltages and the 115VAC control circuit.

27

Page 29
Image 29
Moyer Diebel MH-60M3 Basic Service, Electrical Service, Troubleshooting, Moyer Diebel National Service USA Canada, Tools