INSTALLATION

Water Connections (Cont.)

2.A manual shut-off valve for steam and water (supplied by others) should be installed in the supply line to allow for servicing of the machine. The shut-off valve should be the same size or larger than the supply line.

3.Install a 3/4" pressure reducing valve (PRV) in the water supply line if flow pressure exceeds 20-22 PSI/138-151.8 kPa.

A PRV is standard equipment on Model MH-60. A PRV is not standard equipment on Models MH-6N, MH-6L.

Drain Connections

Refer to Fig. 9

1.MH series models are GRAVITY DRAIN machines equipped with a

1-1/2" O.D. hose connection point.

2.The maximum drain flow rate is 15 gallons/min-56.8 liters/min.

3.Drain height for all models must not exceed 11" (280mm) above floor level.

4.The drain connection is made to the dishwasher from underneath the machine through an access hole in the machine base.

Ventilation

 

NOTE:

 

Ventilation must comply with local sanitary

 

and plumbing codes.

!

CAUTION:

Exhaust air should not be vented into a

 

wall, ceiling, or concealed space of a

 

building. Condensation can cause

 

damage.

11" [280mm]

Above floor level

Figure 9

Drain Hose Connection

1-1/2" O.D.

(Max flow rate = 15 gal/min-56.8 liters/min)