Perform the seven checks listed below in the event that your dishwasher does not operate as expected.

1.All switches are ON

2.Drain-overflow assemby is in place and seated

3.Wash and rinse nozzles are clean

4.Wash and rinse pipe assemblies are installed correctly

5.Scrap screens are properly positioned

6.Thermostat(s) are properly adjusted

7.Detergent and rinse additive dispensers are adequately filled

If a problem still exists, use the following table for troubleshooting

CONDITION

CAUSE

SOLUTION

Machine will not start

Doors not closed

Make sure doors are fully closed

 

Door safety switch faulty

Contact your service agency

 

Start switch faulty

Contact your service agency

 

Main switch off

Check disconnect at main panel

 

Overload protector tripped

Reset overload in Control Box

 

 

 

Machine washes

Extended wash switch in

Push Extended wash switch

constantly

extended wash position

down to the off position

 

 

 

Low or no water

Main water supply is turned off

Turn on house water supply

 

Drain-overflow assembly is not

Place and seat drain-overflow

 

in place and seated

 

 

Machine doors not fully closed

Close doors securely

 

Faulty fill valve

Contact your service agency

 

Machine not filled initially

Push Power switch UP to fill

 

Clogged strainer in fill valve

Clean or replace

 

 

 

Continuous water filling

Stuck or defective Fill Timer

Contact your service agency

 

Fill valve will not close

Clean or replace

 

Drain-overflow not in place

Install drain-overflow assembly

 

 

 

Wash motor not running

Overload protector tripped

Reset overload in Control Box

 

Defective motor

Contact your service agency

 

 

 

Wash tank water

Incoming water temperature

Raise temperature to:

temperature is low

at machine too low

110-140°F/43-60°C for MH60

when in use

 

180°F/82°C for MH-6N

 

 

120°F/49°C-140°F/60°C for MH6L

 

Defective thermometer

Check or replace

 

Defective thermostat

Check for proper setting

 

 

or replace

 

Defective heater element

Check or replace

 

Defective solenoid valve

Check or replace

 

Heater elements

Clean and delime

 

have soil/lime buildup

 

 

 

 

25