Chapter 5 – Call Control Commands 
Multi-Tech Systems, Inc. Wireless GSM/GPRS AT Commands (Document Number S000293I)  29 
Syntax:   Command Syntax: 
 For Algold=1: 
AT+ECHO=<mode>[,<Algold>[,<VolOut>,<Step>,<PcmThRel>,<PcmThMax>]] 
For Algold=6: 
AT+ECHO=<mode>[,<Algold>[,<AlgoParam>,<NoiseThres>,<NmbTaps>,<ConvergenceTime
1>,<ConvergenceTime2>,<NoiseLevelMAX>,<DetectionThreshold>,<CNGAdjust>,<CNGPara
m1>,<CNGParam2>,<CNGGain>,<NmbDelay>]] 
Response Syntax: 
For Algold=1: 
ECHO: <status>,<Algold>,<VolOut>,<Step>,<PcmThRel>,<PcmThMax> 
For Algold=6: 
ECHO: <status>,<Algold>,<AlgoParam>,<NoiseThres>,<NmbTaps>,<ConvergenceTime1>, 
<ConvergenceTime2>,<NoiseLevelMAX>,<DetectionThreshold>,<CNGAdjust>,<CNGParam1
>,<CNGParam2>,<CNGGain>,<NmbDelay>,<NoiseEstimate> 
Command  Possible responses 
AT+CMEE=1 
Note: Enables the use of result code  OK 
AT+SPEAKER? 
 + SPEAKER: 0 
OK 
Note: Speaker ONE and Micro ONE are active 
AT+SIDET=0 
Note: Deactivate the Sidetone  OK 
AT+SIDET? +SIDET: 0,0 
AT+ECHO? 
Note: Read current settings  +ECHO: 0,1,0,6,10,7 
OK 
AT+ECHO=1,1,0,6,10,7 
Note: Active Echo cancellation 1 for Mic/Spk one.  OK 
AT+ECHO? 
Note: Read current settings  +ECHO: 1,1,0,3,10,7 
OK 
AT+ECHO=1,6,30,8000,256 
Note: Activate the Echo cancellation 6  +CME ERROR: 519 
 Note: The new algorithm will be activated after a 
reset of the product 
AT+ECHO? 
Note: Read  the Echo cancellation settings  +ECHO: 6,30,8000,256 
OK 
AT+CFUN=1 
Note: Reset the product  OK 
AT+ECHO? 
Note: Read current settings  +ECHO: 1,6,30,8000,256 
OK 
AT+ECHO=0 
Note: Deactivate the Echo Cancellation  OK 
AT+ECHO=0 
Note: Deactivate the Echo Cancellation  OK 
AT+ECHO=1,6,30,50,256,200, 
550,15,32767,27484,38697,7311,2 
Note: Activate the Echo Cancellation 6 
+CME ERROR:519 
Note: The new algorithm will be activated after a 
reset of the product 
AT+ECHO? 
Note: Read the Echo Cancellation settings  +ECHO: 6,30,50,256,200,550,15,32767,32767, 
27484,38697,7311,2,65535 
OK 
AT+CFUN=1 
Note: Reset the product  OK 
AT+ECHO? 
Note: Read the Echo Cancellation settings  +ECHO: 1,6,30,50,256,200,550,15,32767,32767, 
27484,38697,7311,2,65535 
OK