Multi-Tech Systems MT5634ZBA-DID Data Set Ready DSR Control, Test Commands, Store Dialing Command

Models: MT5634ZBA-DID

1 56
Download 56 pages 16.25 Kb
Page 19
Image 19

MultiModemDID User Guide

 

Chapter 4 - AT Commands, S-Registers, Result Codes

 

 

 

Command:

&Sn

Data Set Ready (DSR) Control

Values:

 

n = 0 or 1

Default:

 

0

Description:

&S0

DSR is always high (on).

 

&S1

DSR goes high only during a connection.

Command:

&Tn

V.54 Test Commands

Values:

 

n = 0, 1, 3 or 6

Default:

 

None

Description:

&T0

Abort. Stops any test in progress.

 

&T1

Initiates local analog loopback test.

 

&T3

Initiates local digital loopback test.

 

&T6

Initiates remote digital loopback test.

Note: To stop a test, you must use the escape sequence (+++AT) before typing

&T0.

 

 

Command:

&V

Display Current Settings

Values:

 

n/a

Description:

 

Displays the active modem settings, including the callback

 

 

security settings if callback security is enabled. If the setup

 

 

password has been entered, it also displays the callback

 

 

security passwords.

Command:

&Wn

Store Current Configuration

Values:

 

n = 0, 1

Default:

 

1

Description:

&W0

Stores current modem settings in nonvolatile memory and

 

 

causes them to be loaded in place of the factory defaults at

 

 

power-on or following the ATZ command. See also the &F

 

 

command.

 

&W1

Clears user default settings from nonvolatile memory and

 

 

causes the factory defaults to be loaded at power-on or

 

 

following the ATZ command.

Command: &Zn=x

Store Dialing Command

Values:

 

n = 0, 1, 2 (callback security disabled)

 

 

x = Dialing command string

Default:

 

None

Description:

 

Stores dialing command x in memory location y. Dial the stored

 

 

number using the command ATDS=n. See also the #CBSn

 

 

command.

Command:

\An

Select Maximum MNP Block Size

Values:

 

n = 0, 1, 2, or 3

Default:

 

3

Description:

\A0

64-character maximum.

 

\A1

128-character maximum.

 

\A2

192-character maximum.

 

\A3

256-character maximum.

19

Page 19
Image 19
Multi-Tech Systems MT5634ZBA-DID manual Data Set Ready DSR Control, Test Commands, Display Current Settings